Thermogravimetry TGA and STA

Simultaneous Thermogravimetry - Differential Scanning Calorimetry TG-DSC measures both heat flow and weight changes in a material as a function of temperature or time in a controlled atmosphere. Simultaneous measurement of these two material properties not only improves productivity but also simplifies interpretation of the results.

The complimentary information obtained allows differentiation between endothermic and exothermic events which have no associated weight loss (e.g., melting and crystallization) and those which involve a weight loss (e.g., degradation).

TGA PT1000

The NEW Linseis TGA PT1000 for thermogravimetric applications is a toploading Thermobalance, which offers a highly userfriendly design. Even at a sample weight of up to 5g the tara is done electronically. The specially designed furnaces allow fast heating and cooling rates from 0.

TGA PT1600

The Linseis TGA PT1600 for thermogravimetric applications is a toploading Thermobalance, which offers a highly userfriendly design. Even at a sample weight of up to 5/25g the tara is done electronically. The specially designed furnaces allow fast heating and cooling rates as well as a highly precise temperature control.

STA PT1000 (TG-DSC/DTA)

The Linseis STA PT1000 is a top loading Thermobalance, which offers a highly user-friendly design. Even at a sample weight of up to 10g the Tara is done electronically. The specially designed furnaces allow fast heating and cooling rates as well as a highly precise temperature control.

STA PT1600 (TG-DSC/DTA)

The STA PT1600 is the high end Simultaneous Thermobalance from LINSEIS. The system offers unparalleled TG and DSC resolution in combination with the highest vacuum capabilities and TG drift stability. The system is modular with many exchangeable furnaces (-150°C up to 2400°C), different measuring systems and crucibles.

STA HP2 TGA-DSC

Thermogravimetry is a technique in which the mass of the sample is monitored against time or temperature while the temperature of the sample, in a specified atmosphere, is programmed. This technique serves the determination of material compositions.

STA HP 3 (high pressure TG-DSC)

High Pressure TG-DSC – Table version
 

Worlds only top loading combined TG-DSC (Thermogravimeter and Differential Scanning Calorimeter). For experiments up to 1200°C and up to 150 bar in reactive or inert atmospheres. Easy user exchangeable TGA or TG-DSC plug and play sensors.

L81-I (DSC-TG)

The TG-DSC LINSEIS L81-I (simultaneous thermal analysis) can be used to determine simultaneous changes of mass Thermogravimetry (TG) and caloric reactions Differential Scanning Calorimeter (DSC) of a sample in the temperature range RT up to 1750°C.

MSB - Magnetic suspension balance

With the magnetic suspension balance LINSEIS MSB PT 1, gravimetric measurements in a wide temperature and pressure range and under aggressive media can be done.